Installer Guide

Before You Redesign the Job: Four Problems Circuit-Level Control Can Help Solve

Four common project challenges, and another way to approach them.

Concept illustration
Concept illustration of circuit-level source selection. The SMART LOAD CENTER is installed indoors.

Ever have a situation where the homeowner is ready to go ahead with solar or storage, but the numbers aren’t working? The utility limits export. The battery quote has grown. An EV charger pushes the service calculation over the limit. Or the inverter can’t supply all the loads the customer wants to run. As the installer, you need to revise the design, explain a higher price, or risk losing the job. Those problems are easier to address when they’re spotted before the proposal is final. One question worth asking early: would controlling the power source circuit by circuit change the design?

Different circuits. Different sources. At the same time.

The SMART LOAD CENTER™ from Koolbridge Energy is a UL 67 listed load center with two isolated power paths: one from the grid, one from your on-site system through its inverter. A circuit uses one source at a time, but the circuits don’t all have to use the same one. In a supported configuration, an EV charger might use available solar power while kitchen circuits remain on the grid. During commissioning, the installer sets source-selection and load priorities for each circuit. The system operates according to those settings, and the homeowner can adjust supported priorities in the app later without rewiring. Traditional panels distribute power. The SLC also controls which available source supplies each circuit. Here’s where that difference matters.

1. The utility limits export, or won't pay for it

Export caps, non-export interconnection requirements, and low credit for surplus solar can shrink a system or stall the application. Two approaches deserve separate consideration. The SLC can supply selected circuits from on-site power while others remain on the grid, but the objective determines how the system needs to be designed: 

  • Zero export, by design. In the reviewed configuration, the on-site source stays physically isolated from the grid. Your own power feeds the circuits you choose and is never fed to the grid. 
  • Use more solar at home. Put flexible loads such as EV charging, water heating, or pool pumps on solar during production hours, so more of the system’s output does useful work in the house. 

 

Using more solar at home doesn’t by itself meet a non-export requirement. Inverter export controls are one way to meet it; the SLC gives you another: a design that keeps your on-site power separate from the grid. 

The complete design still needs the required utility and local approvals. 

For a project constrained by export rules, the relevant details are the utility’s requirements, the proposed inverter configuration, and which household loads could use on-site power. Where export credits are low, those same details can help evaluate whether increasing on-site consumption makes sense.

2. The battery quote stops the sale

The customer wants backup power, but the battery system needed to support every load pushes the quote beyond their budget. 

Adding a second battery may meet the customer’s needs. But more storage and better control over the loads using it aren’t the same thing. Does the customer need more stored energy, or a more selective backup plan? 

With the SLC, installers can set priorities for the circuits connected to it. During an outage, the circuits the customer chooses, such as refrigeration, lighting, internet, and the furnace fan, can run on available battery power while lower-priority loads such as the dryer or pool pump wait for the grid. 

The homeowner can change those priorities later in the app, without rewiring and without a separate critical-loads subpanel. Circuit control decides which loads use the stored energy; it doesn’t add more. You still check starting loads, runtime, and what the inverter and battery can carry. 

Before sizing backup for the entire home, establish which loads need to run during an outage and for how long. With the proposed inverter, battery, and loads identified, an installer can compare additional storage against a design using circuit-level control. The equipment, runtime, and actual project costs still need to be evaluated; neither approach is automatically cheaper.

3. A new load pushes the service past its limit

An EV charger, heat pump, or induction range can push the load calculation past what the existing service supports. A service upgrade adds cost, utility scheduling, and time to the job. 

A lack of open breaker spaces isn’t the same as insufficient service capacity. Before specifying an upgrade, identify which constraint the calculation actually shows. 

The SLC can supply a high-demand circuit, such as an EV charger, from available on-site power while other circuits stay on the grid. Grid fallback has to be managed within an accepted load-management design; switching sources alone does not establish sufficient service capacity. 

Choosing on-site power for a circuit does not by itself avoid an upgrade. If those loads are configured to return to the grid when on-site power isn’t available, they still have to fit the service. The load calculation and the inspector decide. 

The deciding documents are the load calculation, service rating, proposed new loads, and the controls accepted by the authority having jurisdiction (AHJ). They determine whether a load-management approach is viable.

4. The home needs more power than the inverter can deliver

The customer’s loads add up to more than the inverter can supply at one time. The usual answers are a bigger inverter, a second one, or cutting back what the system covers. 

A larger inverter isn’t necessarily the only design to examine. With the SLC, selected circuits can use the inverter’s available output while other circuits remain on the grid. The inverter doesn’t have to carry every household load at once. You set sources and priorities at the breaker, across 16 breaker spaces on the SLC-125 or 32 on the SLC-200. It works with compatible inverters and batteries in supported configurations, including [named systems, such as Sol-Ark and SolarEdge, pending Danny and Magnus confirmation of the published list]. 

A useful evaluation starts with the inverter and battery models, the one-line diagram, and the loads likely to run simultaneously. Confirm the exact equipment, control arrangement, and wiring configuration before committing to a design.

UL 67 listed · 14 issued patents · 10-year limited warranty · Designed and assembled in Wilmington, NC · Certified Installer Program · Installation and Configuration Guide 

Bring us a project

If one of these issues is shaping a current project, share the one-line diagram and the loads that matter. We’ll show where the SLC fits.

Book a project review or email info@koolbridge.com.

Want hands-on time first? Ask about the Smart Load Center Evaluation Program.

Final design depends on load calculation, equipment compatibility, utility requirements, and local review. The SMART LOAD CENTER does not generate or store electricity. It is not a transfer switch and is not for use in emergency, legally required standby, or life-support systems.